KTI – SAUTER CombiMaster contains a complete refrigeration system for active cooling of water and air. Likewise this contains two heating units for heating water and air. Heating and cooling, however, share the periphery. This has the unbeatable advantage that only one water pipe and one air pipe must be laid from the CombiMaster to the concrete batching plant. In addition, the CombiMaster is very compact, as the plants share one machine room. Winter operation In the winter, a KTI – SAUTER hot water system (HWS) heats the fresh water up to +85°C. A KTI – SAUTER hot air system (OLH) is responsible for heating the cold ambient air in order to heat the silos with the hot air. Both systems can be operated independently of each other, which is particularly useful in the transitional period. enormous savings brings with it. Summer operation In summer, a glycol chiller installed on the roof provides the required cooling capacity. The cold glycol is pumped through both a plate heat exchanger and an air register. In the plate heat exchanger Fresh water cooled which is then buffered in the boiler of the hot water system. In the air register, the ambient air is cooled before it flows into the silos. So unlike other products, the CombiMaster actually provides Cold air and not only ambient air is available for rock cooling.
°C Hot air
°C Hot water
°C Cold air
°C Cold water
Gallery
Summer operation of the CombiMaster: Air is actively cooled via a refrigeration system before it flows through the aggregate silos. Cold water is produced at the same time, which is used as feed water.
Winter operation of the CombIMaster: Air is heated to 130-150 °C in the OLH air heater and then flows through the sand and gravel silos. Required water is heated to 40-60 °C with 300 kW heating power.
Schematic structure of the CombiMaster. We recommend an insulated water tank as buffer storage so that the CombiMaster can develop its full power.
KTI - SAUTER CombiMaster in operation at an Austrian concrete producer.
With the KTI – SAUTER CombiWater, you can produce ice water and hot water – with just one system.
The KTI – SAUTER hot water systems (HWS) are used in the production of concrete, especially winter concrete.
The KTI – SAUTER hot air units (OLH) are used in a concrete plant to heat silos in winter.
KTI cold air plants are specially designed to cool large quantities such as gravel and other aggregates efficiently, quickly and economically during concrete production.
KTI containerized water chiller plants are used in the cooling of concrete to provide addition water at 3 – 5 °C.
KTI offers you a complete range of perfectly insulated water tanks.
Our experts will be happy to support you in the planning and implementation of your project.